20

The Dual side burner is factory set to use Propane gas. It is critical that the gas you use matches that
which the side burner was set up for. You can verify that by checking the rating plate.

ORIFICE SIZE/ GRANDEUR DES ORIFIC

PROPANE

NATURAL GAS

GAZ NATURAL

MAIN BURNER/

BRÛLEUR PRINCIPAL

1.1MM

1.46MM

MODEL/ MODÈLE DSB 16”

CLASS NO / CATÉGORIE #:

2711 04/84

-

66902

2 X

12,000

BTU/ POT MAIN BURNERS / BRÛLEUR PRINCIPAL

DSB -ELECTRICAL REQUIREMENTS

:

.

C

N

I

S

T

C

U

D

O

R

P

E

G

A

W

E

N

A

D

A

N

A

C

,

O

I

R

A

T

N

O

,

N

A

H

G

U

A

V

E

N

I

H

C

N

E

E

U

Q

I

R

B

A

F

/

A

N

I

H

C

N

I

E

D

A

M

MINIMUM CLEARANCE TO ADJACENT COMBUSTABLES:

EQUIPPED FOR USE WITH

DÉGAGEMENT MINIMUM AUX COMBUSTIBLES ADJACENTS

INCHES FROM SIDES

1

4

POUCES DES CÔTÉS

INCHES FROM REAR

18

POUCES DE L’ARRIÈRE

OUTDOOR COOKING APPLIANCE- FOR OUTDOOR USE ONLY. IF STORED INDOORS,

DETACH AND STORE GAS CYLINDER OUTSIDE. DO NOT USE THIS APPLIANCE

UNDER OR CLOSE TO UNPROTECTED OVERHEAD COMBUSTABLE SURFACES.

SEE INSTRUCTIONS FOR CLEARANCES.

ONLY FOR INSTALLATION IN A BUILT-IN

ENCLOSURE CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS.

MANIFOLD PRESSURE INCHES OF WATER COLUMN

11” PROPANE / 7” NG

NATURAL GAS / GAZ

PROPANE

MFG DATE DE FABRICATION :

APPAREIL DE CUISINE DE PLEIN AIR- UTILISE À L'EXTÉRIEUR SEULEMENT. SI MAINTENU À

L'INTÉRIEUR, DÉCHARGEZ ET CONSERVEZ LE BONBONNE AU GAZ À L'EXTÉRIEUR.

N'UTILISEZ PAS CET APPAREIL SOUS OU À PROXIMITÉ D’UNE CONSTRUCTION COMBUSTIBLE.

ATTENTION:

L'ALIMENTATION DE GAZ DOIT TOUJOURS ÊTRE FERMEZ À LA SOURCE /

BONBONNE QUAND L'APPAREIL N'EST PAS UTILISÉ

NE GARDER PAS UN BONBONNE AU GAZ PROPANE EN RÉSERVE DESOUS OU À PROXIMITÉ DE CET

APPAREIL.

SI L’INFORMATION PRÉCÉDENTE N’EST PAS SUIVIE EXACTEMENT, UN INCENDIE PROVOQUANT

UNE MORT OU DES BLESSURES GRAVES PEUVENT PRODUIRE.

AVERTISSEMENT

:

UTILISEZ UNIQUEMENT LE RÉGULATEUR DE PRESSION DE GAZ

(PROPANE SEULEMENT) QUI EST FOURNI AVEC CET APPAREIL.

CE RÉGULATEUR EST RÉGLÉ POUR UNE PRESSION DE PRISE DE 11 POUCES DE COLONNE

D'EAU(0.39 PSI)

11 PROPANE/ 7 GN

po

po

111 CREDITVIEW ROAD, 2nd FLOOR

L4L-9T1

X

10”/254MM

2 3/4”/69.8 MM

GENUX to PROVIDE small “X” sticker FOR GAS FITTER TO INSTALL- PROPANE.

FONT FOR BODY 8.89 POINT
FONT FOR WARNINGS 16 POINT
FONT FOR TABLE 7 AND 10 POINT

X X X

PEEL OFF STICKERS

ONLY FOR INSTALLATION IN A BUILT-IN ENCLOSURE

CONSTRUCTED OF NON-COMBUSTIONABLE MATERIALS.
UNIQUEMENT POUR L'INSTALLATION DANS UN BOÎTIER

INTÉGRÉ CONSTRUIT DE MATÉRIAUX NON COMBUSTIBLES

OU POUR BRÛLEUR LATÉRAL.

INPUT- 110 VAC 60 Hz .25A

Class IIIA-2

ANS Z21.58-2018•CSA 1.6-2018

Outdoor Cooking Gas Appliances

®

WARNING:

GAS SUPPLY MUST BE TURNED OFF AT SOURCE/ CYLINDER

WHEN APPLIANCE NOT IN USE. DO NOT STORE A SPARE PROPANE GAS CYLINDER

UNDER OR NEAR THIS APPLIANCE. NEVER FILL THE CYLINDER BEYOND 80% FULL.

IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE CAUSING DEATH

OR SERIOUS INJURY MAY OCCUR.

CAUTION:

USE ONLY THE GAS PRESSURE REGULATOR (PROPANE ONLY)

PROVIDED WITH THIS APPLIANCE. THIS REGULATOR IS SET FOR AN OUTLET PRESSURE

OF 11 INCHES OF WATER COLUMN (2.74 kPa). THE APPLIANCE CAN BE USED WITH

PROPANE GAS AND NATURAL GAS. THIS APPLIANCE IS ADJUSTED AND SHIPPED FOR

USE WITH NATURAL GAS. TO CONVERT TO PROPANE GAS, USE ONLY A SUPPLIED

PROPANE GAS CONVERSION KIT. REFER TO INSTRUCTION MANUAL FOR HELP

WARNING

Gas Connections

Never connect a gas line directly to the grill. A pressure regulator must be installed on all gas

equipment. All local codes require a pressure regulator and NewAge supplies the correct regulator

with your grill. Removing or failing to install the pressure regulator can result in fire, and serious

personal injury and will void the warranty. This grill is designed for non-combustible enclosures

only.

As indicated on the rating plate, this gas grill is designed to operate with gas supply pressure of

11” WC for Propane.

This appliance is certified to be used only with 20 Lbs Propane tank.

If the gas

supply pressure is lower than these requirements, the unit will be under-fired and will not reach

the maximum temperatures. Ensure that the supply line size complies with local and/or national

installation codes.

Rating Plate - Lists model numbers, and gas type
Water Column Requirements

Fuel

WC Min Under

Full Load

PROPANE

11 in wc (LPG)

The rating plate is located in one or more of the following places:

On the underside of the side burner lid

Ensure that the gas supplied meets with the minimum pressure requirements. Do not operate the

Side burner on any gas other than that for which the Side burner has been set.

Both the regulator and the manifold orifices have been tuned for the type of gas specified on the

rating plate.

All installation and all installation parts must conform to local codes with the National Electrical

Code, ANSI Z223.1/ NFPA 70 latest edition and the National Fuel Gas Code, ANSI Z223.1/NFPA 54

in the U.S. and CGA-B149.1/.2 in Canada. Canadian installations must conform to CGA-B149.1/.2

natural gas/propane installation code. (Canada)

WARNING