Installation –
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
$PLQLPXPRI´URXQGGXFWZRUNPXVWEHXVHGWR
PDLQWDLQPD[LPXPDLUÀRZHႈFLHQF\ZLWKWKH
FIPLQWHUQDOEORZHU$PLQLPXPRI´WR´URXQGGXFW
ZRUNPXVWEHXVHGZLWKWKHFIPUHPRWHEORZHU
Always use rigid type metal ducts only. Flexible ducts
FRXOGUHVWULFWDLUÀRZE\XSWR
8VHFDOFXODWLRQRQSDJHWRFRPSXWHWRWDODYDLODEOH
duct run when using elbows, transitions and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
LQFUHDVHGXFWVL]HIURP´WR´RU´,IDUHGXFHU
LVXVHGLQVWDOODORQJUHGXFHULQVWHDGRIDSDQFDNH
reducer. Reduce duct size as far away from opening as
possible.
If turns or transitions are required; install as far
away from opening and as far apart, between 2, as
possible.
Minimum mount height between range top and hood
ERWWRPVKRXOGEHQROHVVWKDQ´
0D[LPXPPRXQWKHLJKWVKRXOGEHQRKLJKHUWKDQ´
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will lose
LWVSHUIRUPDQFHDQGHႈFLHQF\
If available, also refer to range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
Vertical Ducting:
´URXQGPLQLPXPLQWHUQDOEORZHU
´WR´URXQGPLQLPXPUHPRWHEORZHU
Horizontal Ducting:
N/A
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the unit
to the store in which it was bought for repair or
replacement.
• If the unit is damaged by the customer, repair or
replacement is the responsibility of the customer.
,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer and
installer.
26” min.
36” max.
min. A
max. B
min. C
max. D
Standard
Extension
Hood Heights
Duct Cover
Duct Cove
r
minimum (A) 30-1/2”
44“
maximum (B) 49-1/2”
77”
Ceiling Heights
minimum (C) 92-1/2” (7’ 8-1/2”) 106“ (8 10”‘)
maximum (D) 121-1/2” (10’ 1-1/2“) 149” (12’ 5”)