GE PZS22MYKFS - Manuel d'utilisation - Page 13

GE PZS22MYKFS
Téléchargement du manuel

49-1000470 Rev. 1

33

INST

ALLA

TION INSTRUCTIONS

INSTALLING THE REFRIGERATOR

(Cont.)

1

CONNECTING THE
REFRIGERATOR TO THE HOUSE
WATER LINE

(icemaker and dispenser models)

A cold water supply is required for automatic

LFHPDNHUDQGGLVSHQVHURSHUDWLRQ,IWKHUHLV

not a cold water supply, you will need to provide

RQH6HH³,QVWDOOLQJWKH:DWHU/LQH´VHFWLRQ

NOTES:

• Before making the connection to the

refrigerator, be sure the refrigerator power
cord is not plugged into the wall outlet.

‡,I\RXUUHIULJHUDWRUGRHVQRWKDYHDZDWHUILOWHU

we recommend installing one if your water
supply has sand or particles that could clog
the screen of the refrigerator’s water valve.

,QVWDOOLWLQWKHZDWHUOLQHQHDUWKHUHIULJHUDWRU

,IXVLQJ8QLYHUVDO:DWHU/LQH5HIULJHUDWRU
7XELQJ.LW\RXZLOOQHHGDQDGGLWLRQDOWXEH
:;;WRFRQQHFWWKHILOWHU'RQRWFXW

plastic tube to install filter.

A

If you are using copper tubing,

place a

compression nut and ferrule (sleeve) onto the
end of the tubing coming from the house cold
water supply.

If you are using the universal water line
tubing,

the nuts are already assembled to the

tubing.

B

If you are using copper tubing,

insert the end

of the tubing into the refrigerator connection, at
the back of the refrigerator, as far as possible.
While holding the tubing, tighten the fitting.

If you are using universal water line tubing,

insert the molded end of the tubing into the
refrigerator connection, at the back of the
refrigerator, and tighten the compression nut
until it is hand tight. Then tighten one additional
turn with a wrench. Overtightening may cause
leaks.

WARNING

Connect to potable water supply only.

A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).

WARNING

ELECTRIC SHOCK
HAZARD

$WWDFKWXELQJFODPSXVLQJH[LVWLQJKROHRQO\'2

NOT drill into the refrigerator.

C

)DVWHQWKHWXELQJLQWRWKHFODPSSURYLGHGWR

hold it in position. You may need to pry open
the clamp.

Universal Water Line Tubing

´7XELQJ

Tubing Clamp

´

Compression Nut

)HUUXOH

(sleeve)

Refrigerator
Connection

2

TURN ON THE WATER SUPPLY

Turn the water on at the shutoff
valve (house water supply) and
check for any leaks.

3

PLUG IN THE REFRIGERATOR

Before plugging in the refrigerator,
make sure the icemaker switch is
set to the

OFF

position.

See the grounding information
attached to the power cord.

Option 2

Installation Instructions

Universal Water
Line Tubing

Refrigerator
Connection

Option 3

Option 1

Universal Water
Line Tubing

„Téléchargement du manuel“ signifie que vous devez attendre que le fichier soit complètement chargé avant de pouvoir le lire en ligne. Certains manuels sont très volumineux, et le temps de chargement dépend de la vitesse de votre connexion Internet.